• 75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan
  • 75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan
  • 75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan
  • 75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan
  • 75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan
  • 75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan

75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan

Material: Iron
Usage: Mine
Flow Direction: Axial Flow
Samples:
US$ 50/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan pictures & photos
75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan
US $50 / Piece
Min. Order: 1 Piece
Manufacturer/Factory & Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Shandong, China
Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Quality Assurance
The supplier provides quality assurance
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (15)
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
Overview

Basic Info.

Model NO.
FCZ/FBCDZ
Pressure
Low Pressure
Certification
RoHS, UR, ISO, CE, CCC
Color
White, Red, Blue, etc.
Transport Package
Wooden Packing
Specification
Different models, different sizes
Trademark
HENGDING
Origin
China
HS Code
8414513000
Production Capacity
10, 000 Units/Yearv

Packaging & Delivery

Package Size
100.00cm * 100.00cm * 100.00cm
Package Gross Weight
100.000kg
Lead Time
1 days (1 - 1 Pieces)
To be negotiated ( > 1 Pieces)

Product Description

Product Description

 

Product introduction

The FKZ series mining fans are successfully designed based on the original energy-saving mining fans through technological improvements, perfect structures, improved performance and expanded machine sizes. The fan operates with higher efficiency, lower noise, wider performance range, and more significant power saving effect. At the same time, the main air duct is equipped with a flow stabilizing ring device, and the characteristic curve has no hump, which ensures that the fan can operate stably under any resistance state.

In order to expand the performance range of fans and meet the needs of various large, medium and small non-coal mines, various types of ventilation networks with low, medium and high resistance and large, medium and small air volumes can be selected to operate in the high-efficiency zone. fan, auxiliary fan and multi-stage station fans. The fans adopt hub ratios of 0.40 and 0.45 and stand-alone structure types. They use 4, 6 and 8-pole motors respectively. The fans can be designed according to the working condition parameters provided by the user to ensure that the Efficient zone operation.


Product Usage

The fan is specially designed according to the ventilation needs of various mines such as coal mines, metallurgy, non-ferrous metals, gold, chemical industry, building materials and nuclear industries. It can be used as a main fan or an auxiliary fan, and can be installed on the surface or underground. It is suitable for The combined operation of multiple fans is an ideal station fan for each level of station in a multi-fan series multi-level station ventilation system.

Working principle

The ventilator is generally composed of a collector, a host, a diffuser and other components. See the installation basic diagram for details. According to user needs, it can be equipped with diffusion tower, damper, control cabinet, frequency converter, online monitoring and fault diagnosis system.

When the ventilator is used as the main ventilator and station fan, it should be equipped with a special diffuser. The surface main ventilator is equipped with a diffuser that can convert part of the dynamic pressure into static pressure and reduce the outlet dynamic pressure loss to achieve energy saving. The ventilator installed underground is equipped with a diffuser, which can not only reduce the local resistance coefficient, but also reduce the dynamic pressure value at the diffuser outlet, thereby greatly reducing the local resistance of the fan device and saving ventilation power consumption.

The motor is placed in the main barrel, and the power junction box is led out to the ventilator casing through an extension rod. The motor always runs in fresh air flow, which can ensure effective heat dissipation of the motor.

The fan has a compact structure, is safe to use and is easy to maintain. The fan uses a specially designed motor, which has good heat dissipation. The motor can be equipped with a bearing and stator temperature measuring device, and the operating status of the motor can be monitored at any time through an electronic thermometer.

Transportation, Storage

The fan can be transported in sections, and it should be ensured that the components of the fan are not damaged, especially the impeller section is not deformed. When storing the ventilator, you need to choose a dry environment without corrosive gases. If it is stored in the open air, it should be covered with tarpaulin and the ground should be raised 200mm to avoid rain and moisture.

Ventilators are generally transported as a complete unit and can be transported by land or water.

 
Detailed Photos

 

75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan
Product Parameters

 

product name Power Full pressure
Mine primary fan 5.5kW~1250kW 750Pa~20000Pa
Mine secondary fan 1.1kW~550kW 300Pa~7800Pa
Mine booster fan 2×1.1kW~2×250kW 1100Pa~13000Pa

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan pictures & photos
75 Kw Mine Primary Fan, 75 Kw Mine Explosion-Proof Axial Flow Fan
US $50 / Piece
Min. Order: 1 Piece
Gold Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Year of Establishment
2010-09-14
Registered Capital
3.84 Million USD