• 63-Inch 300HP Mining Two-Stage Fan 63 Smj Two Stage Fans
  • 63-Inch 300HP Mining Two-Stage Fan 63 Smj Two Stage Fans
  • 63-Inch 300HP Mining Two-Stage Fan 63 Smj Two Stage Fans
  • 63-Inch 300HP Mining Two-Stage Fan 63 Smj Two Stage Fans
  • 63-Inch 300HP Mining Two-Stage Fan 63 Smj Two Stage Fans

63-Inch 300HP Mining Two-Stage Fan 63 Smj Two Stage Fans

Material: Iron
Usage: Mine
Flow Direction: Axial Flow
Pressure: High Pressure
Certification: RoHS, UR, ISO, CE, CCC
Protection Level: IP55/IP56
Samples:
US$ 30/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Shandong, China
Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Quality Assurance
The supplier provides quality assurance
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (15)
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Insulation Level
F
Power Frequency
50Hz/60Hz
Color
White, Red, Blue, etc.
Diameter of Impeller
300mm~4000mm
Warranty
2 Years
Transport Package
Wooden Packing
Specification
Have many sizes,Can provide according to your need
Trademark
HNDING
Origin
Shandong, China
HS Code
8414593000
Production Capacity
10, 0000 Units/Yearv

Product Description

Product Description

 

To meet the needs of coal mines, the mine energy-saving promotion station of the Ministry of Metallurgy invented the explosion-proof patent technology of the extraction type main fan of the coal mines. The materials used in the machine have passed the friction spark test of the Test Center of China Coal Research Institute Chongqing Branch and achieved the explosion-proof requirements. The explosion-proof performance of the whole machine has passed the explosion-proof inspection of the China National Quality Supervision and Test Centre for Explosion-Protected Electrical Products. It introduces the FBCDZ (formerly BDK62) series of coal mine ground explosion-proof extraction-type counter-rotating axial flow ventilator, which has better performance, more specifications, and larger coverage. The product is subject to the standards of Q / ZFJ001-2004 the Technical Conditions of the FBCDZ (formerly BDK62) Series of Coal Mine Ground Explosion-proof Extraction Type Counter-rotating Axial Flow ventilator.


Characteristics
1. To meet the resistance requirements of the coal mine ventilation network and ensure the efficiency of the ventilator, the machine adopts the counter-rotating structure, that is, two sets of the same model of fans are connected, and the rotation direction of the impellers of the two machines is opposite, which can save the middle guide vane and reduce the loss of the guide vane, thus improving the efficiency.

2. The form of the direct connection between the motor and the impeller is adopted, which changes the traditional structure of the long shaft of the mine main fan or the pulley drive, avoiding damage, and accidentsapipeokisTheThis  several-outa short  of the transmission device, and also eliminates the energy loss of the transmission device and improves the efficiency of the fan device. Due to its simple structure, in addition to regularly filling fuel to the motor bearings, it generally does not require maintenance and can be operated continuously for a long time.

3. When the motor power of this series of fans is less than 200 KW, it is equipped with the YBF series with an explosion-proof type motor of the derived series of YB series, and the voltage is 380V, 660V, or 1140V. When the power is above 200 KW, it can be equipped with YBF series of 6000V high voltage explosion-proof energy-saving type motor according to the needs of the mine. The motor is installed in an airtight, cover in the main air duct. The airtight, cover has a certain pressure resistance. It can isolate the motor from the gas contained in the fan flow passage and also has a certain effect of heat dissipation. The airtight, cover is equipped with two rows of the streamlined air pipe, which are interlinked with the ground atmosphere through the main air duct so that fresh air flows into the airtight cover, and at the same time, the air in the cover can maintain a positive pressure state during the operation of the fan. Due to the use of various technical measures in the design, the motor is always working under the condition that the gas concentration is less than 1%, which meets the safety and explosion-proof requirements.

4. The highest unit of this series of fans can achieve a static pressure efficiency of 86%, the high-efficiency area is wide, and the static pressure efficiency is more than 70% of 70% or more working area. It can ensure that the efficiency of the main fan of the mine in the three mining stages is all above 75%, which has reversed the low operation efficiency of the main fan of large mines in China and saves a large amount of electric energy.

5. A steady flow ring is installed in the main air duct, the performance curve of the fan has no hump, no surge, and it can run stably under any resistance condition. The noise is low. Most models of this product have a noise of less than 90 dB (A) without a muffler. If the user has stricter requirements on noise, the product can be equipped with a muffler when leaving the factory.

6. All the blades of this series of fans can be adjusted, which can be divided into five working angles: 45°, 40°, 35°, 30 and 25°. The installation angles of the front and rear stages can be the same, or different, or can be adjusted to run at any angle below 45º. One of the fans can be operated separately, so the adjustable range is extremely wide. In the initial stage of production of the mine, it is ok to run only one class of the fan of it.

7. This series of fans are stable in operation and low in machine vibration. And the fans and diffusers are installed on the flatbed truck with wheels, which can run continuously for a long time.


8. The reverse wind can be reversed. In various working conditions, the reverse wind rate is all above 60%. There is no need for the reverse air duct, and only a need to build a simple ventilation machine room and an electric control duty room, which can save a lot of infrastructure investment.
 
Detailed Photos

 

63-Inch 300HP Mining Two-Stage Fan 63 Smj Two Stage Fans
63-Inch 300HP Mining Two-Stage Fan 63 Smj Two Stage Fans
63-Inch 300HP Mining Two-Stage Fan 63 Smj Two Stage Fans
 
63-Inch 300HP Mining Two-Stage Fan 63 Smj Two Stage Fans
63-Inch 300HP Mining Two-Stage Fan 63 Smj Two Stage Fans
63-Inch 300HP Mining Two-Stage Fan 63 Smj Two Stage Fans
 
Product Parameters

 

FK series mining fan parameter table

Fan model

Motor Power
(kw)

Air volume
(m3/s)

Full pressure
(Pa)

Dryer diameter
(mm)

Air supply distance

(m)

Fan weight
(kg)

Dimensions
(mm)

D

L

H

FK58-1NO.3

1.5

0.9~1.4

928~575

300

80

51

390

486

230

FK58-1NO.3.5

3

1.5~2.4

1263~752

350

150

74

450

562

260

FK58-1NO.4

5.5

2.2~3.5

1648~1020

400

200

115

520

649

290

FK58-1NO.4.5

11

3.1~5.0

2093~1295

450

300

135

585

728

320

FK58-2NO.4

11

2.2~3.5

2923~1811

400

400

130

520

877

290

FK55-2NO.4.5

11

3.0~5.2

2276~1275

450

300

140

543

704

375

FK55-1NO.5

11

4.2~6.6

1726~1324

450

200

135

600

535

400

FK56-1NO.3.15

2.2

1.4~2.1

853~588

300

80

53

374

634

193

FK56-1NO.4

4

2.1~3.4

1275~981

400

150

96

477

682

240

FK67-1NO.4.5

7.5

2.6~4.2

2256~1177

400

250

145

540

760

270

FK67-2NO.4.5

11

2.8~4.3

3237~1471

400

400

195

540

860

270

FK67-1NO.5.25

28

4.0~6.3

3776~2648

500

600

420

620

1364

310

FK40-1NO.5.5

5.5

4.3~5.1

533~475

550

120

720

653

3800

336

FK40-1NO.6.5

11

7.1~8.4

884~663

650

140

742

772

3800

396

FK40-1NO.7

15

8.8~10.5

1025~769

700

140

795

830

4100

425

FKK40-1NO.7.5

22

10.9~12.9

1177~883

750

150

824

890

4100

455

FK40-1NO.8

30

13.2~15.6

1339~1005

800

150

848

950

4350

485

DFK50-NO.5.5

2×5.5

4.8~5.8

1182~515

550

180

948

653

3800

336

DFK50-NO.6.5

2×11

7.9~9.5

1651~719

650

200

1120

772

3800

396

DFK50-NO.7

2×15

9.9~11.9

1915~834

700

200

1207

830

4100

425

DFK50-NO.7.5

2×22

12.2~14.6

2198~957

750

220

1293

890

4100

455

DFK50-NO.8

2×30

14.8~17.8

2501~1089

800

220

1340

950

4350

485

 
FBD series mining fan parameter table
 
Serial no. Machine no. Air volume (m3/min) Full pressure (Pa) Power (KW)
1 3.5/4.4 133-90 715-1320 2.2×2
2 4/3 111-56 172-1800 1.5×2
3 4/4.4 136-72 251-1880 2.2×2
4 4/6 150-86 351-1956 3×2
5 5/8 210-120 331-2503 4×2
6 5/11 228-132 371-2950 5.5×2
7 5/15 245-150 380-3524 7.5×2
8 5.6/15 274-164 375-3750 7.5×2
9 5.6/22 340-210 405-4418 11×2
10 5.6/30 395-250 450-4470 15×2
11 6.3/30 420-260 413-4950 15×2
12 6.3/37 486-292 513-5130 18.5×2
13 6.3/44 525-310 600-5263 22×2
14 6.3/60 590-390 760-5800 30×2
15 7.1/60 620-396 603-6450 30×2
16 7.1/74 672-480 800-6500 37×2
17 7.1/90 738-400 1100-6700 45×2
18 8.2/74 630-270 420-6900 37×2
19 8.2/90 654-380 600-7600 45×2
20 8.2/110 790-550 680-8200 55×2
21 8.2/150 964-546 700-8600 75×2
22 10/60 1170-814 745-2733 30×2
 
FKZ series mining fan parameter table

 

Model

Machine number

Air volume(m3/S)

Total pressure(Pa)

Power(kW)

K40(FKZ)-4-№

(n=1450r/min)

8

4.4~9.5

108~497

5.5

9

6.2~13.5

136~629

11

10

8.5~18.6

168~776

15

11

11.3~24.7

203~939

30

12

14.7~32.1

242~1118

37

13

18.7~40.8

284~1312

55

14

23.4~50.9

329~1521

90

15

28.7~62.6

378~1746

110

K45(FKZ)-4-№

(n=1450r/min)

8

6.6~12.5

357~685

7.5

9

9.5~17.8

452~867

15

10

13.0~24.0

558~1071

30

11

17.3~32.6

675~1295

45

12

22.5~42.3

804~1542

75

13

28.6~53.8

94.3~1810

90

14

35.7~67.2

1094~2099

132

15

43.9~82.6

1256~2409

200

K40(FKZ)-6-№

(n=980r/min)

7

2.0~4.3

38~174

1.1

8

3.0~6.4

49~227

2.2

9

4.2~9.1

62~287

3

10

5.8~12.5

77~355

5.5

11

7.7~16.7

93~429

7.5

12

9.9~21.7

111~510

15

13

12.6~27.5

130~599

18.5

14

15.8~34.4

150~695

30

15

19.4~42.3

173~798

37

16

23.6~51.4

197~908

55

17

28.3~61.6

222~908

75

18

33.6~73.1

249~1149

90

19

39.5~86.0

277~1280

110

20

46.0~100.3

307~1418

160

21

53.3~116.1

339~1563

200

22

61.3~113.4

372~1716

250

K45(FKZ)-6-№

(n=980r/min)

7

3.0~5.7

125~240

1.5

8

4.5~8.4

163~313

3

9

6.4~12.0

207~396

5.5

10

8.7~16.5

255~489

7.5

11

11.6~22.0

309~592

15

12

15.1~28.5

367~704

18.5

13

19.2~36.3

431~827

30

14

23.9~45.3

500~959

45


FBCDZ series mining fan parameter table

 

Series
 
No.
 
Air volume (m3/s)
Air volume (m3/s)
(Pa)
Full pressure(Pa)
Motor model
 
Power (KW)
 

FBCDZ(B)- 4(n=1450r/min)
12 9.6-29.0 860-3400 YBF250M-4 2×55
13 12.2-37.0 1010-4000 YBF280M-4 2×90
14 15.2-45.6 1170-4630 YBF315M-4 2×132



FBCDZ(A)-6
(n=980r/min)
14 10.1-31.7 918-2888 YBF280M-6 2×55
15 12.4-39.0 1054-3315 YBF315S-6 2×75
16 15.0-47.3 1199-3772 YBF315L1-6 2×110
17 18.0-56.8 1353-4258 YBF315L2-6 2×132
18 21.4-67.4 1517-4774 YBF355M2-6 2×185
19 25.1-79.3 1690-5319 YBF355L1-6 2×220
20 29.3-92.5 1873-5893 YBF355L2-6 2×250
21 33.9-107.0 2065-6497 YBF450M1-6 2×355






FBCDZ(A)-8
(n=740r/min)
17 13.6-42.9 772-2428 YBF315S-8 2×55
18 16.1-50.9 865-2722 YBF315M-8 2×75
19 19.0-60.0 964-3033 YBF315L2-8 2×110
20 22.1-69.8 1068-3360 YBF355M1-8 2×132
21 25.6-80.8 1177-3705 YBF355M2-8 2×160
22 29.5-92.9 1292-4066 YBF355L2-8 2×200
23 33.7-106.2 1412-4444 YBF450S3-8 2×250
24 38.2-120.7 1538-4839 YBF450M2-8 2×315
25 43.2-136.4 1669-5250 YBF450M2-8 2×315
26 48.6-153.4 1805-5679 YBF560M2-8 2×450
27 54.4-171.8 1946-6124 YBF560M2-8 2×450
28 60.7-191.6 2093-6586 YBF630M2-8 2×710





FBCDZ(A)-10
(n=590r/min)
20 17.6-55.7 679-2136 YBF315L-10 2×75
21 20.4-64.4 748-2355 YBF355M1-10 2×90
22 23.5-74.1 821-2585 YBF355M2-10 2×110
23 26.8-84.7 898-2825 YBF355L1-10 2×132
24 30.5-96.2 978-3076 YBF355L2-10 2×160
25 34.5-108.7 1061-3338 YBF355L3-10 2×185
26 38.8-122.3 1147-3610 YBF450M2-10 2×250
27 43.4-137.0 1237-3893 YBF450M2-10 2×250
28 48.4-152.8 1331-4187 JBO710M1-10 2×315
29 53.8-169.7 1427-4491 JBO710M2-10 2×355
 
Series
 
No. Air volume (m3/s) Full pressure(Pa) Motor model
 
Power (KW)
 

FBCDZ(A)-10
(n=590r/min)
30 59.5-187.9 1527-4806 JBO800S2-10 2×450
32 72.3-228.0 1738-5468 JBO900S1-10 2×560
34 86.7-273.4 1962-6173 JBO900S3-10 2×800
36 102.9-324.7 2199-6921 JBO900M2-10 2×1000






FBCDZ(A)-12
(n=490r/min)
 
24 25.3-79.9 674-2122 JBO355S2-12 2×110
25 28.6-90.3 732-2302 JBO355S2-12 2×110
26 32.2-101.6 791-2490 JBO400S-12 2×132
27 36.1-113.8 853-2685 JBO400M-12 2×160
28 40.2-126.9 918-2888 JBO710S1-12 2×200
29 44.7-140.9 985-3098 JBO710S1-12 2×200
30 49.5-156.0 1054-3315 JBO710M1-12 2×250
32 60.0-189.4 1199-3772 JBO800S2-12 2×355
34 72.0-227.1 1353-4258 JBO900S1-12 2×450
36 85.5-269.6 1517-4774 JBO900M1-12 2×560
38 100.5-317.1 1690-5319 JBO900L1-12 2×800
40 171.2-370.0 1873-5893 JBO900L2-12 2×1000



FBCDZ(B)-6
(n=980r/min)


 
15 14.5-36.6 805-2335 YBF280M-6 2×55
16 17.6-44.4 916-2656 YBF315S-6 2×75
17 21.1-53.3 1035-2999 YBF315M-6 2×90
18 25.0-63.3 1160-3362 YBF315L2-6 2×132
19 29.4-74.4 1292-3746 YBF355M1-6 2×160
20 34.3-86.8 1432-4150 YBF355L1-6 2×220
21 39.7-100.5 1579-4576 YBF450S2-6 2×280




FBCDZ(B)-8
(n=740r/min)

 
18 18.9-47.8 661-1917 YBF315S-8 2×55
19 22.2-56.2 737-2136 YBF315M-8 2×75
20 25.9-65.5 816-2367 YBF315L1-8 2×90
21 30.0-75.9 900-2609 YBF355M1-8 2×132
22 34.5-87.2 988-2863 YBF355M2-8 2×160
23 39.4-99.7 1080-3130 YBF355L1-8 2×185
24 44.8-113.2 1176-3408 YBF355L3-8 2×220
25 50.6-128.0 1276-3698 YBF450M1-8 2×280
26 56.9-144.0 1380-3999 YBF560S2-8 2×355
 
Series
 
No.
 
Air volume (m3/s) Full pressure(Pa) Motor model
 
Power (KW)
 
FBCDZ(B)-8
(n=740r/min)
27 63.7-161.0 1488-4313 YBF560S2-8 2×355
28 71.1-179.8 1600-4638 YBF560M2-8 2×450






FBCDZ(B)-10
(n=590r/min)
 
21 23.9-60.5 572-1659 YBF315L-10 2×75
22 27.5-69.5 628-1820 YBF315L-10 2×75
23 31.4-79.5 686-1990 YBF355M1-10 2×90
24 35.7-90.3 747-2166 YBF355M2-10 2×110
25 40.3-102.1 811-2351 YBF355L2-10 2×160
26 45.4-114.8 877-2542 YBF355L3-10 2×185
27 50.8-128.6 946-2742 YBF450S3-10 2×200
28 56.7-143.4 1017-2949 YBF450M2-10 2×250
29 63.0-159.3 1091-3163 YBF450M2-10 2×250
30 69.7-176.4 1168-3385 JBO710M1-10 2×315
32 84.6-214.0 1329-3851 JBO800S2-10 2×450
34 101.5-256.7 1500-4348 JBO900S1-10 2×560
36 120.4-304.7 1682-4874 JBO900M1-10 2×710







FBCDZ(B)-12
(n=490r/min)


 
25 33.5-84.8 559-1621 JBO355S2-12 2×110
26 37.7-95.3 605-1754 JBO355S2-12 2×110
27 42.2-106.8 652-1891 JBO400S-12 2×132
28 47.1-119.1 702-2034 JBO400M-12 2×160
29 52.3-132.3 753-2182 JBO400M-12 2×160
30 57.9-146.5 806-2335 JBO710S1-12 2×200
32 70.3-177.7 916-2656 JBO710M1-12 2×250
34 84.3-213.2 1035-2999 JBO800S1-12 2×315
36 100.0-253.1 1160-3362 JBO900S1-12 2×450
38 117.6-297.6 1292-3746 JBO900M1-12 2×560
40 137.2-347.2 1432-4150 JBO900M2-12 2×710
42 158.8-401.9 1579-4576 JBO900L2-12 2×1000
44 182.6-462.1 1733-5022 JBO900L3-12 2×1250

 

Company Profile

 

63-Inch 300HP Mining Two-Stage Fan 63 Smj Two Stage Fans
63-Inch 300HP Mining Two-Stage Fan 63 Smj Two Stage Fans

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Year of Establishment
2010-09-14
Registered Capital
3.84 Million USD